# Fluke 117 Electricians Multimeter with Non-Contact Voltage

**Type:** Product page · **SKU:** CE04616 · **Brand:** [Core Electronics](https://core-electronics.com.au/brands/core-electronics-australia)
**Page:** https://core-electronics.com.au/fluke-117-electricians-multimeter-with-non-contact-voltage.html ([markdown](https://core-electronics.com.au/fluke-117-electricians-multimeter-with-non-contact-voltage.html.md))

The Fluke 117 Electrician's Multimeter with Non-Contact Voltage is a compact true-rms meter for commercial applications. The Fluke 117 is the ideal meter for demanding...

## Pricing

- **Price:** $469.95 (inc GST) — $427.23 AUD, exc GST
- **Quantity discounts:** 3+ $414.68 (exc GST) · 5+ $406.32 (exc GST)

## Availability & dispatch

- In stock, ships same business day if ordered before 2PM (Australia/Sydney).
- We can dispatch 1 today, and up to 16 more in 4–15 days.

## Description

The Fluke 117 Electrician's Multimeter with Non-Contact Voltage is a compact true-rms meter for commercial applications. The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster.

### Features

- VoltAlert™ technology for non-contact voltage detection
- AutoVolt automatic ac/dc voltage selection
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- True-rms for accurate measurements on non-linear loads
- Measures 10 A (20 A overload for 30-seconds)
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™) for hands free operation
- CAT III 600 V safety rated
 
 | ### Specifications |
|---|
| Maximum voltage between any terminal and earth ground | \|  \| 600 V \| |
|---|
| Surge protection | \|  \| 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 \| |
|---|
| Fuse for A input | \|  \| 11 A, 1000 V FAST Fuse (Fluke PN 803293) \| |
|---|
| Display | \| Digital: \| 6,000 counts, updates 4 per second \| |
|---|
| Bar graph | \|  \| 33 segments, updates 32 per second \| |
|---|
| Operating Temperature | \|  \| -10 °C to + 50 °C \| |
|---|
| Storage Temperature | \|  \| -40 °C to + 60 °C \| |
|---|
| Battery type | \|  \| 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 \| |
|---|
| Battery Life | \|  \| 400 hours typical, without backlight \| |
|---|

 | ### Accuracy Specifications |
|---|
| DC millivolts | \| Range: \| 600.0 mV \| \| Resolution: \| 0.1 mV \| \| Accuracy: \| ± (\[% of reading\] + \[counts\]): 0.5% + 2 \| |
|---|
| DC volts | \| Range/Resolution: \| 6.000 V / 0.001 V \| \| Range/Resolution: \| 60.00 V / 0.01 V \| \| Range/Resolution: \| 600.00 V / 0.1 V \| \| Accuracy: \| ± (\[% of reading\] + \[counts\]): 0.5% + 2 \| |
|---|
| Auto volts | \| Range: \| 600.0 V \| \| Resolution: \| 0.1 V \| \| Accuracy: \| 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) \| |
|---|
| AC millivolts1 true-rms | \| Range: \| 600.0 mV \| \| Resolution: \| 0.1 mV \| \| Accuracy: \| 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) \| |
|---|
| AC volts1 true-rms | \| Range/Resolution: \| 6.000 V / 0.001 V \| \| Range/Resolution: \| 60.00 V / 0.01 V \| \| Range/Resolution: \| 600.0 V / 0.1 V \| \| Accuracy: \| 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) \| |
|---|
| Continuity | \| Range: \| 600 Ω \| \| Resolution: \| 1 Ω \| \| Accuracy: \| Beeper on &lt; 20 Ω, off &gt; 250 Ω; detects opens or shorts of 500 μs or longer. \| |
|---|
| Ohms | \| Range/Resolution: \| 600.0 Ω / 0.1 Ω \| \| Range/Resolution: \| 6.000 kΩ / 0.001 kΩ \| \| Range/Resolution: \| 60.00 kΩ / 0.01 kΩ \| \| Range/Resolution: \| 600.0 kΩ / 0.1 kΩ \| \| Range/Resolution: \| 6.000 MΩ / 0.001 MΩ \| \| Accuracy: \| 0.9 % + 1 \| \| Range/Resolution: \| 40.00 MΩ / 0.01 MΩ \| \| Accuracy: \| 5 % + 2 \| |
|---|
| Diode Test | \| Range/Resolution: \| 2.000 V / 0.001 V \| \| Accuracy: \| 0.9% + 2 \| |
|---|
| Capacitance | \| Range/Resolution: \| 1000 nF / 1 nF \| \| Range/Resolution: \| 10.00 μF / 0.01 μF \| \| Range/Resolution: \| 100.0 μF / 0.1 μF \| \| Range/Resolution: \| 9999 μF / 1 μF \| \| Range/Resolution: \| 100 μF to 1000 μF \| \| Accuracy: \| 1.9% + 2 \| \| Range/Resolution: \| &gt; 1000 μF \| \| Accuracy: \| 5% + 20% \| |
|---|
| LoZ capacitance | \| Range: \| 1 nF to 500 μF \| \| Accuracy: \| 10% + 2 typical \| |
|---|
| AC amps true-rms (45 Hz to 500 Hz) | \| Range/Resolution: \| 6.000 A / 0.001 A \| \| Range/Resolution: \| 10.00 A / 0.01 A \| \| Accuracy: \| 1.5% + 3 \| \|  \| 20 A continuous overload for 30 seconds max \| |
|---|
| DC amps | \| Range/Resolution: \| 6.000 A / 0.001 A \| \| Range/Resolution: \| 10.00 A / 0.01 A \| \| Accuracy: \| 1.0% + 3 \| \|  \| 20 A continuous overload for 30 seconds max \| |
|---|
| Hz (V or A input)2 | \| Range/Resolution: \| 99.99 Hz / 0.01 Hz \| \| Range/Resolution: \| 999.99 Hz / 0.1 Hz \| \| Range/Resolution: \| 9.999 Hz / 0.001 Hz \| \| Range/Resolution: \| 50.00 Hz / 0.01 Hz \| \| Accuracy: \| 0.1% + 2 \| |
|---|

### Shipping List

- 4 mm PVC TL75 lead set
- Yellow protective sheathe
- User manual
 
Notes:
1\) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2\) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3\) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4\) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

 | ### General Specifications |
|---|
| Size | \|  \| 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") \| |
|---|
| Weight | \|  \| 550 g \| |
|---|
| Warranty | \|  \| 3 years \| |
|---|

## Images

- [Product image 1](https://core-electronics.com.au/media/catalog/product/f/l/flu117.jpg)